15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Still deciding? Get samples of US$ 140/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
8000000 RMB
Plant Area
>2000 square meters
  • 15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex
  • 15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex
  • 15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex
  • 15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex
  • 15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex
  • 15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex
Find Similar Products
  • Overview
  • Product Description
  • Application
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
RT-127T- W15
Ruler Length
0-15m
Ruler Cable
White
Coating
ETFE
Conductor
Silver Plated Copper
Scale
Metric and British
Transport Package
Carton
Specification
0-15m, 0-30m, 0-37m
Trademark
no
Origin
Shanghai, China
HS Code
8544491100
Production Capacity
5000/1 Month

Packaging & Delivery

Package Size
40.00cm * 30.00cm * 30.00cm
Package Gross Weight
0.700kg

Product Description

 

15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex

15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic Uti Tape Model Gtex and Rtex
 
Cable width
12.5mm~13mm
Cable thickness
0.75mm~0.85mm
Ruler width
10mm±0.2mm
Coating
Coating material resistance to chemical and acid
Specification
15M
Color
white
Product Description

special characteristics

Coating material resistance to chemical and acid.
High temperature resistance

Tank Gauging Tape MMC UTI Flexi Dip D 2401-2

Restricted and Open Gauging Tapes provide a convenient and accurate means for measuring ullage, product temperature and the oil-water interface. The units are configured to operate in the trimode, bimode, interface or temperature mode. Each instrument is designed to maximize ease of use. A single penetration of each tank can provide comprehensive data about internal tank conditions. When the electronic probe senses hydrocarbon, a steady tone is heard; when sensing water, it emits an intermittent tone. Temperature is shown on an LED display in the hub of the instrument.

SPECIFICATIONS
Accuracy

  • of Tape: +/- 1/8″ (+/- 3mm), +/- 0.01% of F.S. tape LGT (F.S. = Full Scale).
  • of Temperature Display: +/- 0.5° F (+/- 0.2° C) +/- 1 digit error.
  • of Calibration Range: 32° F (0° C) to 176° F (88° C).
  • of Probe: For dryness to within 3/8 inch (10mm) of bottom.Ambient Temperature Limits
  • LCD: same as above.
  • Sensor: same as above.

Application:

  • Open gauging ("O" type) (Safe product vapors only).
  • Restricted gauging ("R" type) via MMC vapor-control valve.

Battery: 9-Volt  MN1604.
Operation: U-Ullage, I-Interface (oil/water), T-Temperature.


Coating material resistance to chemical and acid.

High temperature resistance

UTI (Ullage Temperature Interface) is a detector used to measure the ullage, temperature, and the oil-water interface onboard tankers. On this page, we examine the UTI functions, principles of working and the importance of its annual calibration.   

What is Ullage Temperature Interface (UTI)?

The UTI detector is a portable liquid level gauge that is commonly used in the shipping industry to measure the amount of hydrocarbons and chemicals in a ship's tank. This device includes a sensor probe, measurement tape, display unit, and winding drum. Its primary purpose is to determine the temperature and oil-water interface on tankers by attaching the sensor probe to the measurement tape, which can vary in length from 15m to 40m. Manufacturers offer a temperature range between -40°C and 110°C. All UTI meters have earth grounding capabilities for safety purposes.

Note: It is very important that the Ullage Temperature Interface system is grounded to the tank before the probe is introduced into the tank and remains grounded until after complete withdrawal from the tank.

Temperature Detection

The sensing component of the UTI detector is a Platinum Resistance Temperature Detector (RTD). This element is situated in the temperature electrode that is filled with a heat transfer compound paste to hasten the latency. After digitizing the RTD element signal, the micro-controller in the sensor probe corrects and compensates for any errors. The RTD element's attributes are saved in the sensor memory and are exclusively for that sensor, so a new calibration is not required when replacing the sensor. The micro-controller sends the data to the Display Unit that can be read by the technician.

Interface Detection

The operating principle for oil-water interface level detection of the UTI detector involves measuring conductivity between an active electrode and a grounded electrode. When the liquid measured is conductive (e.g., water), the ullage sensor detects its existence. Afterwards, the conductivity electrodes and their related electronic circuits modify the coded signal generating an intermittent beep sound.


ULLAGE TEMPERATURE INTERFACE DETECTOR is necessary for cargo tanker and it is designed for measuring the ullage level, the oil-water interface level, the temperature sampling the cargo.
hermetic GTEX RTEX OTEX uti tape
GT3 MK3 UTI meter
MMC uti tape d-2401-2
TANKTECH uti tapp meter T2000-TFC-02 T2000-TFC-01
MARSEN uti tape

15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex
15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex
Application

Suitable for ULLAGE INTERFACE TEMPERATURE DETECTOR

15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex
Packaging & Shipping

15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex

15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex
Company Profile

15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex

15meter Oil Water Interface Detector Gauging Rtex Gtex UTI Tape Tape Only for Hermetic UTI Tape Model Gtex and Rtex
FAQ

 


Q 1: I didn't find my needed model in this page.
Answer: Dear Friends, e-catalog will emailed to you asap when you contact with us. Also, we supply customization service. So,contact us !

Q 2: What's your Minimum Order Quantity?
Answer: 1PC

Q 3: When can I get the price and what's the validity?
Answer: usually within one day.Validity is 30 days

Q 4: What's your payment terms?
Answer: By T/T 30% in advance ; Balance 70% before shipment. 

Q 5: What's your delivery time?
Answer: It depends on whether we just have the stock for your type. Or, it takes about 10 - 30 days for normal orders.

Q 6: What's your package method ?
Answer: Usually, cartons
Any other questions please contact with us freely:)

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now