Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter

Product Details
Customization: Available
After-sales Service: Available
Warranty: Half Year Without Huaman Damage
Still deciding? Get samples of US$ 130/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
8000000 RMB
Plant Area
>2000 square meters
  • Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
  • Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
  • Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
  • Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
  • Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
  • Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
Find Similar Products

Basic Info.

Model NO.
uti tape
Ruler Cable
Yellow
Coating
ETFE
Conductor
Silver Plated Copper
Lead Time
3 Days
Transport Package
Carton
Specification
0-15m, 0-30m, 0-35m
Trademark
no
Origin
Shanghai, China
HS Code
8544491100
Production Capacity
5000/1 Month

Packaging & Delivery

Package Size
25.00cm * 25.00cm * 6.00cm
Package Gross Weight
1.000kg
Lead Time
18 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)

Product Description

 

Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter

portable oil water interface detector mmc d2401-2 15M uti tape meter
Cable width
12.5mm~13mm
Cable thickness
0.75mm~0.85mm
Ruler width
10mm±0.2mm
Coating
Coating material resistance to chemical and acid
Specification
15M
Color
yellow

special characteristics
Coating material resistance to chemical and acid.
High temperature resistance

Tank Gauging Tape MMC UTI Flexi Dip D 2401-2

Restricted and Open Gauging Tapes provide a convenient and accurate means for measuring ullage, product temperature and the oil-water interface. The units are configured to operate in the trimode, bimode, interface or temperature mode. Each instrument is designed to maximize ease of use. A single penetration of each tank can provide comprehensive data about internal tank conditions. When the electronic probe senses hydrocarbon, a steady tone is heard; when sensing water, it emits an intermittent tone. Temperature is shown on an LED display in the hub of the instrument.

SPECIFICATIONS
Accuracy

  • of Tape: +/- 1/8″ (+/- 3mm), +/- 0.01% of F.S. tape LGT (F.S. = Full Scale).
  • of Temperature Display: +/- 0.5° F (+/- 0.2° C) +/- 1 digit error.
  • of Calibration Range: 32° F (0° C) to 176° F (88° C).
  • of Probe: For dryness to within 3/8 inch (10mm) of bottom.Ambient Temperature Limits
  • LCD: same as above.
  • Sensor: same as above.

Application:

  • Open gauging ("O" type) (Safe product vapors only).
  • Restricted gauging ("R" type) via MMC vapor-control valve.

Battery: 9-Volt 
Operation: U-Ullage, I-Interface (oil/water), T-Temperature.

Coating material resistance to chemical and acid.
High temperature resistance
Coating material resistance to chemical and acid.
High temperature resistance

HERMetic UTImeter Gtex and Otex is a portable gas tight liquid level gauge designed for closed gauging of hydrocarbons and chemicals. It ensures increased safety and efficiency in cargo control measurement, custody transfer, temperature verification and free water detection on marine vessels.
Coating material resistance to chemical and acid.
High temperature resistance
UTI (Ullage Temperature Interface) is a detector used to measure the ullage, temperature, and the oil-water interface onboard tankers. On this page, we examine the UTI functions, principles of working and the importance of its annual calibration. MMC's UTI gauging tapes are capable of detecting all floating and non-conductive hydrocarbons. Each instrument is designed for ease of use. Gauging for liquid or interface level is accomplished simply and quickly. When the electronic probe is lowered and senses a hydrocarbon, a steady horn tone is sounded and a yellow LED illuminates. When sensing an oil-water interface or a non-conductive liquid heavier than water, an intermittent horn tone sounds and a red LED starts flashing.


UTI (Ullage Temperature Interface) is a detector used to measure the ullage, temperature, and the oil-water interface onboard tankers. On this page, we examine the UTI functions, principles of working and the importance of its annual calibration.   

What is Ullage Temperature Interface (UTI)?

The UTI detector is a portable liquid level gauge that is commonly used in the shipping industry to measure the amount of hydrocarbons and chemicals in a ship's tank. This device includes a sensor probe, measurement tape, display unit, and winding drum. Its primary purpose is to determine the temperature and oil-water interface on tankers by attaching the sensor probe to the measurement tape, which can vary in length from 15m to 40m. Manufacturers offer a temperature range between -40°C and 110°C. All UTI meters have earth grounding capabilities for safety purposes.

Note: It is very important that the Ullage Temperature Interface system is grounded to the tank before the probe is introduced into the tank and remains grounded until after complete withdrawal from the tank.

How does Ullage Temperature Interface (UTI) work?
In the following paragraphs, we will introduce how the ullage, temperature and oil-water interface are detected onboard:

Ullage Detection

The ullage detector of the UTI integrates two elements (1) electronic circuits and (2) two piezoceramic plates. When the sensor head reaches the oil or petroleum, an ultrasonic sound is emitted. The receiver processes and sends this sound to the instrument unit that emits a continuous beep sound.

Temperature Detection

The sensing component of the UTI detector is a Platinum Resistance Temperature Detector (RTD). This element is situated in the temperature electrode that is filled with a heat transfer compound paste to hasten the latency. After digitizing the RTD element signal, the micro-controller in the sensor probe corrects and compensates for any errors. The RTD element's attributes are saved in the sensor memory and are exclusively for that sensor, so a new calibration is not required when replacing the sensor. The micro-controller sends the data to the Display Unit that can be read by the technician.

Interface Detection

The operating principle for oil-water interface level detection of the UTI detector involves measuring conductivity between an active electrode and a grounded electrode. When the liquid measured is conductive (e.g., water), the ullage sensor detects its existence. Afterwards, the conductivity electrodes and their related electronic circuits modify the coded signal generating an intermittent beep sound.

What types of Ullage Temperature Interface (UTI) exist?

UTI meters can be either open or closed types, with the latter having a gas-tight body to prevent hazardous gases from escaping the measurement tank.
 

UTI (Ullage, Temperature, Interface) is an ultrasonic measure that integrates 3 functions in 1: Measuring Ullage in the tank, Temperature temperature and oil/water interface. Combining the first 3 letters of 3 features should be called UTI. The device is used mainly on oil vessels, chemical vessels and general liquid cargo tank depots.

There are not many UTI manufacturers for oil/chemical vessels, it is relatively specific and picky customers. Famous companies include MMC, HERMetic (Tanksystems), Tanktech, Marsen, Rongde.

ULLAGE TEMPERATURE INTERFACE DETECTOR is necessary for cargo tanker and it is designed for measuring the ullage level, the oil-water interface level, the temperature sampling the cargo.
hermetic GTEX RTEX OTEX uti tape
GT3 MK3 UTI meter
MMC uti tape d-2401-2
TANKTECH uti tapp meter T2000-TFC-02 T2000-TFC-01
MARSEN uti tape
Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter

Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter


Suitable for ULLAGE INTERFACE TEMPERATURE DETECTOR
Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape MeterPortable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape MeterPortable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter
Portable Oil Water Interface Detector MMC D2401-2 15m UTI Tape Meter

Q 1: I didn't find my needed model in this page.
Answer: Dear Friends, e-catalog will emailed to you asap when you contact with us. Also, we supply customization service. So,contact us !

Q 2: What's your Minimum Order Quantity?
Answer: 1PC

Q 3: When can I get the price and what's the validity?
Answer: usually within one day.Validity is 30 days 

Q 4: What's your payment terms?
Answer: By T/T 30% in advance ; Balance 70% before shipment. 

Q 5: What's your delivery time?
Answer: It depends on whether we just have the stock for your type. Or, it takes about 10 - 30 days for normal orders.

Q 6: What's your package method ?
Answer: Usually, cartons
Any other questions please contact with us freely:)

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now